Check Valve
Operating principle
The valve opens when the pressure of the fluid exceeds the pressure exerted by the pump spring.When the two pressures are equalised, the valve closes.A stronger counter-pressure allows the valve to close
Materials
·Casing/shaft:AISI 316L
·Spring:AISI 304
·SeaI:EPDM according to FDA 177.2600
·Surface finishing:Ras0.8pm
Options
·Seals in NBR FPM (Viton) or PTFE. All of them according to FDA
177.2600
·Connectionsweld,thread,clamp,DIN, SMS, RJT, IDF, ISO,3A
Technical specifications
.Max. pressure 10 bar
·Opening pressure: 0.3 bar (DN-25)
0.2 bar (DN-32/40)
0.1 bar (DN-50/100)
·Working temperature -10℃ to +120℃ (EPDM)